Structural Assessment and Seismic Retrofit of a 7-storey hotel

Program: Seismobuild

This section showcases complete structural models, categorized by the software used for their development (SeismoBuild or SeismoStruct). You can download the project files for each model and open them directly in the corresponding software on your computer to explore the modeling process, parameter settings, and analysis results firsthand.

These are two models for the structural assessment and strengthening of a 7-storey building and basement. The seismic retrofit was carried out with RC jackets, new shear walls, new wing walls and FRP wrapping. The analyses were carried out with the Nonlinear Static Procedure, employing pushover analysis. The model has been created by Alfakat S.A.